Release Notes

Press Esc to stop autoboot ... 0
8. After the installation completes, the system displays the following DELL EMC prompt:
DellEMC>
Upgrading the CPLD
The S5048F-ON system with Dell EMC Networking OS Version 9.14(2.10) requires System complex programmable logic device
(CPLD) 1 revision 1, CPLD2 revision 1, CPLD3 revision 1, CPLD4 revision 1, MSS FPGA revision 0.1, MSS IAP revision 1.4, and
OOB-FPGA revision 1.0.
NOTE: If your CPLD revisions are higher than the ones shown here, DO NOT make any changes. If you have questions
regarding the CPLD revision, contact Technical Support.
Verify that you need a CPLD upgrade
To identify the CPLD version, use the show revision command.
DellEMC#show revision
-- Stack unit 1 --
S5048F-ON CPLD 1 : 1.0
S5048F-ON CPLD 2 : 1.0
S5048F-ON CPLD 3 : 1.0
S5048F-ON CPLD 4 : 1.0
S5048F-ON MSS FPGA : 0.1
S5048F-ON MSS IAP : 1.4
S5048F-ON OOB-FPGA : 1.0
To view the CPLD version that is associated with the Dell EMC Networking OS image, use the following command:
DellEMC#show os-version
RELEASE IMAGE INFORMATION :
---------------------------------------------------------------------
Platform Version Size ReleaseTime
S-Series:S5048F-ON 9.14(2.10) 62789040 May 18 2021 13:53:48
TARGET IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
runtime 9.14(2.10) Control Processor passed
BOOT IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
boot flash 3.38.2.6 Control Processor passed
BOOTSEL IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
boot selector 3.38.0.1-4 Control Processor passed
FPGA IMAGE INFORMATION :
---------------------------------------------------------------------
Card FPGA Name Version
stack-unit 1 S5048F-ON CPLD 1 1.0
stack-unit 1 S5048F-ON CPLD 2 1.0
17