Setup Guide

Table Of Contents
Version Description
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.4(0.0) Added support for the disabled-ports parameter .
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.11.4 The brief parameter no longer displays the current Reload mode. To display Reload mode, use the
show reload-type command. Modified the show system stack-unit command output to
support Piece Part ID (PPID).
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.8.1.0 The Boot Flash field displays the code level for boot code 2.8.1.1 and newer, while older boot codes
display as "Present".
7.7.1.0 Added Master Priority field.
7.6.1.0 Introduced on the S-Series.
Example (show
system brief)
Example (Z9100
ON)
DellEMC# show system stack-unit 1
-- Unit 1 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : Z9100-ON - 34-port TE/TF/FO/FI/HU G (Z9100-ON)
Current Type : Z9100-ON - 34-port TE/TF/FO/FI/HU G (Z9100-ON)
Master priority : NA
Hardware Rev : 0.0
Num Ports : 130
Up Time : 3 day, 19 hr, 3 min
Dell EMC Networking OS Version : 9.13(0.0)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : 3.23.2.13
Boot Selector : 3.23.0.2-7
Memory Size : 3203289088 bytes
Temperature : 37C
Voltage : ok
Serial Number : NA
Part Number : 0GTG6M Rev X02
Vendor Id : NA
Date Code : NA
Country Code : NA
Piece Part ID : CN-03GT5N-77931-58A-0004
PPID Revision : X02
Service Tag : 1XVSG02
Expr Svc Code : 422 556 134 6
Auto Reboot : enabled
Burned In MAC : 4c:76:25:e5:e5:40
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed Power AvgPower AvgPowerStartTime
---------------------------------------------------------------------------------------
0 1 up AC up 5760 128 136 12/14/2017-14:47
1 2 down UNKNOWN down 0 0 0 N/A
144
Control and Monitoring