Release Notes

--------------------------------------------------------------------
1 49 UNKNOWN UNKNOWN USC1D6J No**
1 50 QSFP 40GBASE-LR4 UQ90C7B No**
1 51 QSFP 40GBASE-SR4 7503835V009Y Yes
1 52 QSFP 40GBASE-CR4 10190002 No
1 53 QSFP 40GBASE-SR4 FE2429470007 Yes
1 54 Media not present or accessible
** Interface is down(error disabled) as transceiver is not F10Qualified
DellEMC# show interfaces fortyGigE 1/49
fortyGigE 1/49 is up, line protocol is down(error-disabled[Transceiver Unsupported])
...
The following features are not available in the Dell EMC Networking OS from version 9.7(0.0):
PIM ECMP
Static IGMP join (ip igmp static-group)
IGMP querier timeout configuration (ip igmp querier-timeout)
IGMP group join limit (ip igmp group join-limit)
You can use the negotiation auto command to turn auto-negotiation on or off only on fiber interfaces operating at 1G
speed.
If you use the interface range command to select multiple interfaces that are added to the management VRF, the
ipv6 address command does not display the autoconfig option. You can configure the autoconfig command on
individual interfaces.
If you use the interface range command to select multiple interfaces that are added to the management VRF, the
ipv6 nd command displays the following options but they do not take effect if you use them:
dns-server
hop-limit
managed-config-flag
max-ra-interval
mtu
other-config-flag
prefix
ra-guard
ra-lifetime
reachable-time
retrans-timer
suppress-ra
REST API does not support AAA authentication.
Do not configure the vxlan-instance command on the port, which is configured with the portmode hybrid
command. Do not configure the vxlan-instance enabled port as a member of VLAN, which does not have VXLAN-VNI
configuration.
Half-Duplex mode is not supported.
When FRRP is enabled in a VLT domain, no flavor of Spanning tree should concurrently be enabled on the nodes of that
specific VLT domain. In essence FRRP and xSTP should not co-exist in a VLT environment.
Changes to Default Behavior and CLI Syntax
The following behavior and CLI changes are applicable to the S4048TON switch with Dell EMC Networking OS version
9.14(2.10):
None.
Documentation Corrections
This section describes the errors identified in the current release of the Dell EMC Networking OS.
None.
4