FPGA IMAGE INFORMATION :
---------------------------------------------------------------------
Card FPGA Name Version
stack-unit 1 S4048TON SYSTEM CPLD 12
stack-unit 1 S4048TON MASTER CPLD 13
DellEMC#
Upgrading the CPLD Image
NOTE: The upgrade fpga-image stack-unit 1 booted command is hidden when using the FPGA Upgrade
feature in the CLI. However, it is a supported command and will be accepted when entered as documented.
To upgrade the CPLD image on S4048T-ON, follow these steps:
1. Upgrade the CPLD image.
EXEC Privilege Mode
upgrade fpga-image stack-unit <id> booted
DellEMC#upgrade fpga-image stack-unit 1 booted
Current information for the system:
========================================================================
Card Device Name Current Version New Version
------------------------------------------------------------------------
Unit1 S4048TON SYSTEM CPLD 12 12
Unit1 S4048TON MASTER CPLD 13 13
***********************************************************************
* Warning - Upgrading FPGA is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Proceed with caution ! *
***********************************************************************
Upgrade image for stack-unit 1 [yes/no]: yes
FPGA upgrade in progress!!! Please do NOT power off the unit!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Upgrade result :
================
Unit 1 FPGA upgrade successful Unit 1. Please power cycle to take effect.
DellEMC#May 18 06:35:00: %S4048T-ON:1 %DOWNLOAD-6-FPGA_UPGRADE: stack-unit 1 fpga
upgrade success.
DellEMC#
2. Power cycle the system physically. Switch off the system by unplugging the power chords from the REAR PSUs and wait
until the PSU FAN–REAR STATUS LED is completely OFF.
NOTE: Do not switch on the system with PSU–REAR LED glowing AMBER.
You can alternatively power cycle the switch using the power-cycle stack-unit <1-6> command as follows:
DellEMC#power-cycle stack-unit 1
Proceed with power-cycle? Confirm [yes/no]:yes
3. The CPLD version can be verified using show revision command output:
EXEC Privilege Mode
show revision
DellEMC#sh revision
-- Stack unit 1 --
11