To create access and trunk ports, use the following commands.
Access port a port on the service provider edge that directly connects to the customer. An access port may belong to
only one service provider VLAN.
Trunk port a port on a service provider bridge that connects to another service provider bridge and is a member of
multiple service provider VLANs.
Physical ports and port-channels can be access or trunk ports.
1. Assign the role of access port to a Layer 2 port on a provider bridge that is connected to a customer.
INTERFACE mode
vlan-stack access
2. Assign the role of trunk port to a Layer 2 port on a provider bridge that is connected to another provider bridge.
INTERFACE mode
vlan-stack trunk
3. Assign all access ports and trunk ports to service provider VLANs.
INTERFACE VLAN mode
member
To display the VLAN-Stacking configuration for a switchport, use the show config command from INTERFACE mode.
Enable VLAN-Stacking for a VLAN
To enable VLAN-Stacking for a VLAN, use the following command.
Enable VLAN-Stacking for the VLAN.
INTERFACE VLAN mode
vlan-stack compatible
To display the status and members of a VLAN, use the show vlan command from EXEC Privilege mode. Members of a
VLAN-Stacking-enabled VLAN are marked with an M in column Q.
Configuring the Protocol Type Value for the Outer VLAN Tag
The tag protocol identifier (TPID) field of the S-Tag is user-configurable.
To set the S-Tag TPID, use the following command.
Select a value for the S-Tag TPID.
CONFIGURATION mode
vlan-stack protocol-type
The default is 9100.
To display the S-Tag TPID for a VLAN, use the show running-config command from EXEC privilege mode. Dell EMC
Networking OS displays the S-Tag TPID only if it is a non-default value.
Service Provider Bridging