Install Guide

Table Of Contents
The following example shows the show fip-snooping system command.
DellEMC# show fip-snooping system
Global Mode : Enabled
FCOE VLAN List (Operational) : 1, 100
FCFs : 1
Enodes : 2
Sessions : 17
The following example shows the show fip-snooping vlan command.
DellEMC# show fip-snooping vlan
* = Default VLAN
VLAN FC-MAP FCFs Enodes Sessions
---- ------ ---- ------ --------
*1 - - - -
100 0X0EFC00 1 2 17
FCoE Transit Configuration Example
The following illustration shows a switch used as a FIP snooping bridge for FCoE traffic between an ENode (server blade) and
an FCF (ToR switch). The ToR switch operates as an FCF and FCoE gateway.
Figure 38. Configuration Example: FIP Snooping on a Switch
In this example, DCBx and PFC are enabled on the FIP snooping bridge and on the FCF ToR switch. On the FIP snooping bridge,
DCBx is configured as follows:
A server-facing port is configured for DCBx in an auto-downstream role.
An FCF-facing port is configured for DCBx in an auto-upstream or configuration-source role.
The DCBx configuration on the FCF-facing port is detected by the server-facing port and the DCB PFC configuration on both
ports is synchronized. For more information about how to configure DCBx and PFC on a port, refer to the Data Center Bridging
(DCB) chapter.
The following example shows how to configure FIP snooping on FCoE VLAN 10, on an FCF-facing port (), on an ENode
server-facing port (), and to configure the FIP snooping ports as tagged members of the FCoE VLAN enabled for FIP snooping.