NOTE: If you enter <CR> after entering the recurring command parameter, and you have already set a one-time
daylight saving time/date, the system uses that time and date as the recurring setting.
To view the clock summer-time recurring parameters, use the clock summer-time <time> recurring ? command.
Dell(conf)#clock summer-time pacific recurring ?
<1-4> Week number to start
first Week number to start
last Week number to start
<cr>
Dell(conf)#clock summer-time pacific recurring
Dell(conf)#02:10:57: %SYSTEM-P:CP %CLOCK-6-TIME CHANGE: Summertime configuration changed
from
"Summer time starts 00:00:00 Pacific Sat Mar 14 2009 ; Summer time ends 00:00:00 pacific
Sat Nov
7 2009" to "Summer time starts 02:00:00 Pacific Sun Mar 8 2009;Summer time ends 02:00:00
pacific
Sun Nov 1 2009"
Configuring a Custom-defined Period for NTP time
Synchronization
You can configure the system to send an audit log message to a syslog server if the time difference from the NTP server is
greater than a threshold value (offset-threshold). However, time synchronization still occurs. To configure the offset-threshold,
follow this procedure.
Specify the threshold time interval before which the system generates an NTP audit log message if the system time deviates
from the NTP server.
CONFIGURATION mode
ntp offset-threshold threshold-value
The range for threshold-value is from 0 to 999.
Dell(conf)#ntp offset-threshold 9
970