Deployment Guide

Table Of Contents
When multiple snmp-server host commands are given for the same host and type of notification
(trap or inform), each succeeding command overwrites the previous command. Only the last snmp-
server host command will be in effect. For example, if you enter an snmp-server host inform
command for a host and then enter another snmp-server host inform command for the same host,
the second command replaces the first command.
The snmp-server host command is used with the snmp-server enable command. Use the
snmp-server enable command to specify which SNMP notifications are sent globally. For a host
to receive most notifications, at least one snmp-server enable command and the snmp-server
host command for that host must be enabled.
NOTE: For v1 / v2c trap configuration, if the community-string is not defined using the snmp-
server community command prior to using this command, the default form of the snmp-server
community command automatically is configured with the community-name the same as specified in
the snmp-server host command.
Configuring Informs
To send an inform, use the following steps:
1. Configure a remote engine ID.
2. Configure a remote user.
3. Configure a group for this user with access rights.
4. Enable traps.
5. Configure a host to receive informs.
Related
Commands
snmp-server enable traps enables SNMP traps.
snmp-server community configures a new community SNMPv1 or SNMPv2c.
snmp-server location
Configure the location of the SNMP server.
C9000 Series
Syntax
snmp-server location text
To delete the SNMP location, use the no snmp-server location command.
Parameters
text
Enter an alpha-numeric text string, up to 55 characters long.
Defaults Not configured.
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
Simple Network Management Protocol (SNMP) and Syslog 1617