Format (as specified in RFC 3411): 12 octets.
The first four octets are set to the private enterprise number.
The remaining eight octets are the MAC address of the chassis.
remote
ip-
address
Enter the keyword remote followed by the IP address that identifies the copy of
the SNMP on the remote device.
vrf
management
(OPTIONAL) Enter the keyword vrffollowed by the keyword management to
specify that management vrf will be used to reach the remote host.
udp-port
port-
number engineID
Enter the keywords udp-port followed by the user datagram protocol (User
Datagram Protocol) port number on the remote device. The range is from 0 to
65535. The default is 162.
Defaults As above.
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
Usage
Information
Changing the value of the SNMP Engine ID has important side effects. A users password (entered on
the command line) is converted to a message digest algorithm (MD5) or secure hash algorithm (SHA)
security digest. This digest is based on both the password and the local Engine ID. The command line
password is then destroyed, as required by RFC 2274. Because of this deletion, if the local value of
the Engine ID changes, the security digests of SNMPv3 users is invalid and the users will have to be
reconfigured.
For the remote Engine ID, the host IP and UDP port are the indexes to the command that are matched to
either overwrite or remove the configuration.
Related
Commands
show snmp engineID displays the SNMP engine and all the remote engines that are configured on the
router.
show running-config snmp displays the SNMP running configuration.
snmp-server group
Configure a new SNMP group or a table that maps SNMP users to SNMP views.
C9000 Series
Syntax
snmp-server group [group_name {1 | 2c | 3 {auth | noauth | priv}}] [read
name] [write name] [notify name] [access access-list-name | ipv6 access-
list-name | access-list-name ipv6 access-list-name]]
To remove a specified group, use the no snmp-server group [group_name {v1 | v2c |
v3 {auth | noauth | priv}}] [read name] [write name] [notify name] [access
Simple Network Management Protocol (SNMP) and Syslog 1613