Deployment Guide

Table Of Contents
show pe errors
Display the port extender error logs.
C9000 Series
Syntax
show pe errors
Default None
Command Modes
EXEC
EXEC Privileged
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
In the following example, the Te 1/16 is added as a cascade interface in PE 9, but Te1/16 is connected to
a different PE, which is not provisioned. Hence, the cascade interface is kept in error state.
Example
Dell#show pe errors
PE-id: Not Assigned
PE MAC: f8:b1:56:00:01:04
Interface Errors:
TenGigabitEthernet 1/16 - Error State
Dell#show pe 9
Codes: A - Active, I - Inactive
SVC - Software Version Compatible
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present, PVE - Port Validation Error
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 9
Status: online
System Mac: f8:b1:56:00:01:28
PE Up Time: 08:36:56
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 1/9(A),Te 1/16(I)
Cascade LAG: Po 267(Up)
----------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
---------------------------------------------------------------------
0 online - C1048P f8:b1:56:00:02:24 52
1 online - C1048P f8:b1:56:00:01:28 52
2 online - C1048P f8:b1:56:00:01:90 52
3 online - C1048P 00:00:ab:00:00:2c 52
1352
Port Extenders (PE)