Deployment Guide

Table Of Contents
TOS: 0 Metric: 1
LS age: 9
Options: (No TOS-capability, No DC, E)
LS type: Summary Network
Link State ID: 192.68.32.0
Advertising Router: 1.1.1.10
LS Seq Number: 0x80000016
Checksum: 0x987c
Length: 28
Network Mask: /24
TOS: 0 Metric: 1
LS age: 7
Options: (No TOS-capability, No DC, E)
LS type: Summary Network
Link State ID: 192.68.33.0
Advertising Router: 1.1.1.10
LS Seq Number: 0x80000016
Checksum: 0x1241
Length: 28
Network Mask: /26
TOS: 0 Metric: 1
Related
Commands
show ip ospf database displays OSPF database information.
show ip ospf interface
Display the OSPF interfaces configured. If OSPF is not enabled on the switch, no output is generated.
C9000 Series
Syntax
show ip ospf [process-id | vrf vrf-name] interface [interface]
Parameters
process-id
Enter the OSPF Process ID to show a specific process. If no Process ID is entered,
command applies only to the first OSPF process.
vrf
vrf-name
Enter the keyword vrf and the name of the VRF to view the OSPF processes that
are tied to a specific VRF.
interface
(OPTIONAL) Enter the following keywords and slot/port or number information:
For the null interface, enter the keyword null then zero (0).
For loopback interfaces, enter the keyword loopback then a number from 0 to
16383.
For tunnel interfaces, enter the keyword tunnel then a number from 0 to
16383.
For Port Channel groups, enter the keywords port-channel then a number.
The range is from 1 to 128.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
For a VLAN, enter the keyword vlan then the VLAN ID. The range is from 1 to
4094.
For a port extender (PE) Gigabit Ethernet interface, enter the keyword peGigE
then the pe-id / stack-unit / port-id information.
For a port extender 10-Gigabit Ethernet interface, enter the keyword
peTenGigE then the pe-id / stack-unit / port-id information. The pe-id range
is from 0 to 255; the stack-unit unit-number range is from 0 to 7; and the
port-id range is 25 to 28 or 49 to 52 depending on the PE.
1202 Open Shortest Path First (OSPFv2 and OSPFv3)