White Papers

Table Of Contents
Table 132. show npiv devices Field Descriptions (continued)
Field Description
FCoE VLAN ID of the dedicated VLAN used to transmit FCoE traffic from a server CNA to a fabric
and configured on both the server-facing FN IOM with the FC Flex IO module port and
server CNA port.
Fabric Map Name of the FCoE map containing the FCoE/FC configuration parameters for the
server CNA-fabric connection.
Enode WWPN Worldwide port name of the server CNA port.
Enode WWNN Worldwide node name of the server CNA.
FCoE MAC Fabric-provided MAC address (FPMA). The FPMA consists of the FC-MAP value in
the FCoE map and the FC-ID provided by the fabric after a successful FLOGI. In the
FPMA, the most significant bytes are the FC-MAP; the least significant bytes are the
FC-ID.
FC-ID FC port ID provided by the fabric.
LoginMethod Method used by the server CNA to log in to the fabric; for example, FLOGI or FDISC.
Secs Number of seconds that the fabric connection is up.
State Status of the fabric connection: logged in.
show fc switch Command Example
Dell# show fc switch
Switch Mode : NPG
Switch WWN : 10:00:5c:f9:dd:ef:10:c0
Dell#
Table 133. show fc switch Command Description
Field Description
Switch Mode Fibre Channel mode o f operation of the FN IOM with the FC Flex IO module. Default:
NPG (configured as an NPIV proxy gateway).
Switch WWN Factory-assigned worldwide node (WWN) name of the FN IOM with the FC Flex IO
module. The FN IOM with the FC Flex IO module WWN name is not user-configurable.
FC Flex IO Modules 965