White Papers

Table Of Contents
Priorities:0 1 2 4 5 6 7
PG:1 TSA:ETS BW:50 PFC:ON
Priorities:3
Table 130. show qos dcb-map Field Descriptions
Field Description
State Complete: All mandatory DCB parameters are correctly configured. In progress:
The DCB map configuration is not complete. Some mandatory parameters are not
configured.
PFC Mode PFC configuration in the DCB map: On (enabled) or Off.
PG Priority group configured in the DCB map.
TSA Transmission scheduling algorithm used in the DCB map: Enhanced Transmission
Selection (ETS).
BW Percentage of bandwidth allocated to the priority group.
PFC PFC setting for the priority group: On (enabled) or Off.
Priorities 802.1p priorities configured in the priority group.
show npiv devices brief Command Example
Dell# show npiv devices brief
Total NPIV Devices = 2
-----------------------------------------------------------------------------------------
---------------
ENode-Intf ENode-WWPN FCoE-Vlan Fabric-Intf Fabric-Map
LoginMethod Status
-----------------------------------------------------------------------------------------
---------------
Te 0/12 20:01:00:10:18:f1:94:20 1003 Fc 0/5 fid_1003
FLOGI LOGGED_IN
Te 0/13 10:00:00:00:c9:d9:9c:cb 1003 Fc 0/0 fid_1003
FDISC LOGGED_IN
Table 131. show npiv devices brief Field Descriptions
Field Description
Total NPIV Devices Number of downstream ENodes connected to a fabric over the FN IOM with the FC
Flex IO module, NPG.
ENode-Intf FN IOM with the FC Flex IO module Ethernet interface (slot/port) to which a server
CNA is connected.
ENode-WWPN Worldwide port name (WWPN) of a server CNA port.
FCoE-Vlan VLAN ID of the dedicated VLAN used to transmit FCoE traffic to and from the fabric.
Fabric-Intf Fabric-facing Fibre Channel port (slot/port) on which FC traffic is transmitted to the
specified fabric.
FC Flex IO Modules 963