White Papers

Table Of Contents
Table 127. Displaying NPIV Proxy Gateway Information (continued)
Command Description
show npiv devices [brief]
Displays information on FCoE and FC devices currently logged in to the
NPG.
show fc switch
Displays the FC mode of operation and worldwide node (WWN) name of the
FN IOM with the FC Flex IO module.
show interfaces status Command Example
Dell# show interfaces status
Port Description Status Speed Duplex Vlan
Fc 0/0 Up 8000 Mbit Auto --
Fc 0/1 Down Auto Auto --
Fc 0/2 Down Auto Auto --
Fc 0/3 Down Auto Auto --
Fc 0/4 Down Auto Auto --
Fc 0/5 Down Auto Auto --
Fc 0/6 Down Auto Auto --
Fc 0/7 Down Auto Auto --
Fc 0/8 Down Auto Auto --
Fc 0/9 Down Auto Auto --
Fc 0/10 Down Auto Auto --
Fc 0/11 Down Auto Auto --
Te 1/12 Down Auto Auto --
Te 1/13 Down Auto Auto --
Te 1/14 Down Auto Auto --
Te 1/15 Down Auto Auto --
Te 1/16 Down Auto Auto --
Te 1/17 Down Auto Auto --
Te 1/18 Down Auto Auto --
Te 1/19 Up 10000 Mbit Full --
Te 1/20 Down Auto Auto --
Te 1/21 Down Auto Auto --
Table 128. show interfaces status Field Descriptions
Field Description
Port Server-facing 10GbE Ethernet (Te), 40GbE Ethernet (Fo), or fabric-facing Fibre
Channel (Fc) port with slot/port information.
Description Text description of port.
Status Operational status of port:
Ethernet ports - up (transmitting FCoE and LAN storage traffic) or down (not
transmitting traffic).
Fibre Channel ports - up (link is up and transmitting FC traffic) or down (link is down
and not transmitting FC traffic), link-wait (link is up and waiting for FLOGI to complete
on peer SW port), or removed (port has been shut down).
Speed Transmission speed (in Megabits per second) of Ethernet and FC iports, including
auto-negotiated speed (Auto).
Duplex Data transmission mode: Full (allows communication in both directions at the same
time), Half (allows communication in both directions but not at the same time), Auto
(auto-negotiated transmission).
VLAN VLAN IDs of the VLANs in which the port is a member.
FC Flex IO Modules 961