White Papers

Table Of Contents
Mode Default Settings
Auth/Acct; Auth
coming up)
DHCP Enabled n client only mode
Internet Group
Management
Protocol (IGMP)
v2 & v3
Enabled
Auto LACP LAG Enabled on all ports (Uplink created by default based on LACP PDU)
All VLANS Available on all server and uplink ports
Ensuring the FN IOM system is in Standalone Mode
To ensure that the FN IOM is in Standalone Mode, use the show system stack-unit 0 iom-mode command.
Dell#show system stack-unit 0 iom-mode
Unit Boot-Mode Next-Boot
------------------------------------------------
0 standalone
If the FN IOM system is not in the Standalone Mode, reset the system to its factory default state. To reset the system, use the
restore factory-defaults stack-unit 0 clear-all command. It brings the system in standalone (preconfigured)
mode and sets all configuration settings to a known state.
Dell#restore factory-defaults stack-unit 0 clear-all
Proceed with factory settings? Confirm [yes/no]:y
Configuration Examples
Following are the configuration examples for common upstream switches. To establish a functional uplink and bring the network
ports on PowerEdge FC-Series servers up (FC830, FC630, FC430, FC 620, and FC420) use the following steps:
1. Ensure that the FN IOM system is in Standalone Mode.
2. Create a LACP LAG on the upstream top of rack switch.
3. Verify the connection.
By default the network ports on the PowerEdge FC-Series servers installed in the FX2 chassis is down, until the uplink port
channel is operational on the FN IOM system. It is due to an Uplink Failure Detection, by that when upstream connectivity fails;
the FN IOM disables the downstream links.
You can disable the UFD on a preconfigured FN IOM using the following commands:
Dell#configure
Dell(conf)#uplink-state-group 1
Dell(conf-uplink-state-group-1)#no enable
Dell#show uplink-state-group
Uplink State Group: 1 Status: Disabled, Down
To re-enable UFD, use the following commands:
Dell#configure
Dell(conf)#uplink-state-group 1
Dell(conf-uplink-state-group-1)#enable
Dell#show uplink-state-group
Uplink State Group: 1 Status: Enabled, Up
Sample FN IOM commands and outputs
58
Getting Started