White Papers

Table Of Contents
How FIP Snooping is Implemented
As soon as the Aggregator is activated in an Dell PowerEdge FX2 server chassis as a switch-bridge, existing VLANspecific
and FIP snooping auto-configurations are applied. The Aggregator snoops FIP packets on VLANs enabled for FIP snooping
and allows legitimate sessions. By default, all FCoE and FIP frames are dropped unless specifically permitted by existing FIP
snooping-generated ACLs.
FIP Snooping on VLANs
FIP snooping is enabled globally on an Aggregator on all VLANs:
FIP frames are allowed to pass through the switch on the enabled VLANs and are processed to generate FIP snooping ACLs.
FCoE traffic is allowed on VLANs only after a successful virtual-link initialization (fabric login FLOGI) between an ENode and
an FCF. All other FCoE traffic is dropped.
Atleast one interface is auto-configured for FCF (FIP snooping bridge FCF) mode on a FIP snooping-enabled VLAN.
Multiple FCF trusted interfaces are auto-configured in a VLAN.
A maximum of eight VLANs are supported for FIP snooping on an Aggregator. FIP snooping processes FIP packets in traffic
only from the first eight incoming VLANs.
FC-MAP Value
The FC-MAP value that is applied globally by the Aggregator on all FCoE VLANs to authorize FCoE traffic is auto-configured.
The FC-MAP value is used to check the FC-MAP value for the MAC address assigned to ENodes in incoming FCoE frames. If
the FC-MAP values does not match, FCoE frames are dropped. A session between an ENode and an FCF is established by the
switch bridge only when the FC-MAP value on the FCF matches the FC-MAP value on the FIP snooping bridge.
Bridge-to-FCF Links
A port directly connected to an FCF is auto-configured in FCF mode. Initially, all FCoE traffic is blocked; only FIP frames are
allowed to pass.
FCoE traffic is allowed on the port only after a successful FLOGI request/response and confirmed use of the configured
FC-MAP value for the VLAN.
Impact on other Software Features
FIP snooping affects other software features on an Aggregator as follows:
MAC address learning: MAC address learning is not performed on FIP and FCoE frames, which are denied by ACLs
dynamically created by FIP snooping in server-facing ports in ENode mode.
MTU auto-configuration: MTU size is set to mini-jumbo (2500 bytes) when a port is in Switchport mode, the FIP snooping
feature is enabled on the switch, and the FIP snooping is enabled on all or individual VLANs.
Link aggregation group (LAG): FIP snooping is supported on port channels on ports on which PFC mode is on (PFC is
operationally up).
FIP Snooping Prerequisites
On an Aggregator, FIP snooping requires the following conditions:
A FIP snooping bridge requires DCBX and PFC to be enabled on the switch for lossless Ethernet connections (refer to
Data
Center Bridging (DCB)
). Dell recommends that you also enable ETS; ETS is recommended but not required. DCBX and
PFC mode are auto-configured on Aggregator ports and FIP snooping is operational on the port. If the PFC parameters in a
DCBX exchange with a peer are not synchronized, FIP and FCoE frames are dropped on the port.
VLAN membership:
The Aggregator auto-configures the VLANs which handle FCoE traffic. You can reconfigure VLAN membership on a port
(vlan tagged command).
Each FIP snooping port is auto-configured to operate in Hybrid mode so that it accepts both tagged and untagged VLAN
frames.
FIP Snooping