In case of a failover, the new master switch starts the required timers for the FCoE database tables. Timers run only on the
master stack unit.
NOTE: As a best practice, Dell Networking recommends not configuring FIP Snooping on a stacked switch.
Using FIP Snooping
There are four steps to configure FCoE transit.
1. Enable the FCoE transit feature on a switch to maintain FIP snooping information on the switch.
2. Enable FIP snooping globally on all virtual local area networks (VLANs) or individual VLANs on a FIP snooping bridge.
3. Configure the FC-Map value applied globally by the switch on all VLANs or an individual VLAN.
4. Configure FCF mode for a FIP snooping bridge-to-FCF link.
For a sample FIP snooping configuration, refer to Configuring FIP Snooping.
Important Points to Remember
Enable DCBx on the switch before enabling the FIP Snooping feature.
To enable the feature on the switch, configure FIP Snooping.
To allow FIP frames to pass through the switch on all VLANs, enable FIP snooping globally on a switch.
A switch can support a maximum eight VLANs. Configure at least one FCF/bridge-to-bridge port mode interface for any FIP
snooping-enabled VLAN.
You can configure multiple FCF-trusted interfaces in a VLAN.
When you disable FIP snooping:
ACLs are not installed, FIP and FCoE traffic is not blocked, and FIP packets are not processed.
The existing per-VLAN and FIP snooping configuration is stored. The configuration is re-applied the next time you enable
the FIP snooping feature.
Enabling the FCoE Transit Feature
The following sections describe how to enable FCoE transit.
NOTE: FCoE transit is disabled by default. To enable this feature, you must follow the Configuring FIP Snooping procedure.
As soon as you enable the FCoE transit feature on a switch-bridge, existing VLAN-specific and FIP snooping configurations are
applied. The FCoE database is populated when the switch connects to a converged network adapter (CNA) or FCF port and
compatible DCB configurations are synchronized. By default, all FCoE and FIP frames are dropped unless specifically permitted
by existing FIP snooping-generated ACLs. You can reconfigure any of the FIP snooping settings.
If you disable FCoE transit, FIP and FCoE traffic are handled as normal Ethernet frames and no FIP snooping ACLs are
generated. The VLAN-specific and FIP snooping configuration is disabled and stored until you re-enable FCoE transit and the
configurations are re-applied.
Enable FIP Snooping on VLANs
You can enable FIP snooping globally on a switch on all VLANs or on a specified VLAN.
When you enable FIP snooping on VLANs:
FIP frames are allowed to pass through the switch on the enabled VLANs and are processed to generate FIP snooping ACLs.
FCoE traffic is allowed on VLANs only after a successful virtual-link initialization (fabric login FLOGI) between an ENode and
an FCF. All other FCoE traffic is dropped.
You must configure at least one interface for FCF (FIP snooping bridge-bridge) mode on a FIP snooping-enabled VLAN. You
can configure multiple FCF trusted interfaces in a VLAN.
A maximum of eight VLANS are supported for FIP snooping on the switch. When enabled globally, FIP snooping processes
FIP packets in traffic only from the first eight incoming VLANs. When enabled on a per-VLAN basis, FIP snooping is
supported on up to eight VLANs.
280
FCoE Transit