White Papers

Table Of Contents
Reason Description
Error Bit set For a legacy DCBx version, a peer has sent packets with an error bit set. This reason displays only when a
remote peer is willing to receive a DCB configuration.
Enabled with ETS
Mismatch (show
interfaces
dcbx output)
DCBx is enabled but an ETS validation failure error has occurred.
PFC is
down (show
interfaces
pfc output)
One of the following PFC-specific errors has occurred:
No MBC support.
Configured PFC priorities exceed maximum PFC capability limit.
New dot1p-to-queue mapping violates the allowed system limit for PFC Enable status per priority
ETS is
down (show
interfaces
ets output)
One of the following ETS-specific errors occurred in ETS validation:
Unsupported PGID
A priority group exceeds the maximum number of supported priorities.
COSQ is mapped to more than one priority group.
COSQ is mapped to more than one priority group. - Invalid or unsupported transmission selection
algorithm (TSA).
Bandwidth is configured for an unconfigured priority group.
Total ETS bandwidth mapped in priority groups is not equal to 100%.
Priorities mapped to a queue use different TSAs.
Total bandwidth assigned to priorities in one or more priority groups is not equal to 100%.
Or one of the following ETS failure errors occurred:
Incompatible priority group ID (PGID).
Incompatible bandwidth (BW) allocation.
Incompatible TSA.
Incompatible TC BW.
Incompatible TC TSA.
Data Center Bridging (DCB) 251