Users Guide

Table 115. MIB Objects to Display support for 25G, 40G, 50G, 100G Optical Transceiver or DAC cable
IDPROM user info (continued)
MIB Object OID Description
dellNetIfTransceiverDataTable 1.3.6.1.4.1.6027.3.11.1.3.1 Specifies the Transceiver Data Table
dellNetIfTransceiverDataEntry 1.3.6.1.4.1.6027.3.11.1.3.1.1 Specifies the Transceiver Data Entry
Point
dellNetIfTransDeviceName 1.3.6.1.4.1.6027.3.11.1.3.1.1.1 Specifies the Transceiver Device name
dellNetIfTransPort 1.3.6.1.4.1.6027.3.11.1.3.1.1.2 Specifies the Transceiver Port Name
dellNetIfTransOpticsPresent 1.3.6.1.4.1.6027.3.11.1.3.1.1.3 Specifies whether Optics is present in
the Port or not
dellNetIfTransOpticsType 1.3.6.1.4.1.6027.3.11.1.3.1.1.4 Specifies the Optic Type inserted
dellNetIfTransVendorName 1.3.6.1.4.1.6027.3.11.1.3.1.1.5 Specifies the Vendor Name of the Optic
inserted
dellNetIfTransPartNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.6 Specifies the Part Number of the Optic
inserted
dellNetIfTransSerialNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.7 Specifies the Serial Number of the Optic
inserted
dellNetIfTransTransmitPowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.8 Specifies Lane 1 Tx power value in dBm
dellNetIfTransTransmitPowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.9 Specifies Lane 2 Tx power value in dBm
dellNetIfTransTransmitPowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.10 Specifies Lane 3 Tx power value in dBm
dellNetIfTransTransmitPowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.11 Specifies Lane 4 Tx power value in dBm
dellNetIfTransReceivePowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.12 Specifies Lane 1 Rx power value in dBm
dellNetIfTransReceivePowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.13 Specifies Lane 2 Rx power value in dBm
dellNetIfTransReceivePowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.14 Specifies Lane 3 Rx power value in dBm
dellNetIfTransReceivePowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.15 Specifies Lane 4 Rx power value in dBm
dellNetIfTransTemperature 1.3.6.1.4.1.6027.3.11.1.3.1.1.16 Specifies Temperature value of the
Optics inserted
SNMP Example Output (Single Interface)
DellEMC$ snmpwalk -v 2c -c public -m all -M 10.16.150.140 .1.3.6.1.4.1.6027.3.11.1.3 |
grep 2112517
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransDeviceName.2112517 = STRING: "stack-
unit-1 port-31"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPort.2112517 = STRING: "Fo 1/49/1"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsPresent.2112517 = INTEGER: true(1)
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsType.2112517 = STRING: "40GBASE-
LR4"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransVendorName.2112517 = STRING: "FINISAR
CORP."
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPartNumber.2112517 = STRING: "FTL4C1QE1C-
FC"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransSerialNumber.2112517 = STRING: "UNF0FKU"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane1.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane2.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane3.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane4.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane1.2112517 = STRING:
"-1.433315" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane2.2112517 = STRING:
"0.051805" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane3.2112517 = STRING:
"-0.270108" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane4.2112517 = STRING:
"-0.134970" dBm
856
Simple Network Management Protocol (SNMP)