Setup Guide

Table Of Contents
FIPS Mode : disabled
Boot Flash : 3.26.2.10
Boot Selector : 3.26.0.3
Memory Size : 3177136128 bytes
Temperature : 24C
Voltage : ok
Serial Number : NA
Part Number : 083R0P Rev X01
Vendor Id : NA
Date Code : NA
Country Code : NA
Piece Part ID : 0008
PPID Revision : X01
Service Tag : N/A
Expr Svc Code : 0
Auto Reboot : enabled
Burned In MAC : 14:18:77:09:36:00
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed Power AvgPower AvgPowerStartTime
-------------------------------------------------------------------------------------
1 1 down UNKNOWN down 0 0 0 N/A
1 2 up UNKNOWN up 18816 114 114 12/17/2017-19:15
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed
------------------------------------------------------------------------------------
1 1 up up 22000
1 2 up up 22000
1 3 up up 22000
1 4 absent
1 5 up up 22000
Speed in RPM
show tech-support
Display a collection of data from other show commands, necessary for Dell EMC Networking technical support to perform
troubleshooting.
Syntax
show tech-support [stack-unit unit-id | page]
Parameters
stack-unit (OPTIONAL) Enter the keywords stack-unit to view CPU memory usage for the
stack member designated by unit-id.
page (OPTIONAL) Enter the keyword page to view 24 lines of text at a time. Press the
SPACE BAR to view the next 24 lines. Press the ENTER key to view the next line
of text.
When using the pipe command ( | ), enter one of these keywords to filter command
output. For details about filtering commands, refer to CLI Basics.
save Enter the keyword save to save the command output.
flash: Save to local flash drive (flash://filename. A maximum of 20
characters.
Command Modes EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.14(0.0) Updated to display the show revision and show os-version command
outputs.
136 Control and Monitoring