Release Notes
Table Of Contents
- Dell EMC Networking S3100 Series Release Notes, OS Version 9.14(2.10)
- Document Revision History
- Requirements
- New Dell EMC Networking OS Version 9.14(2.10) Features
- Restrictions
- Changes to Default Behavior and CLI Syntax
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Upgrade Instructions
- Support Resources
New Dell EMC Networking OS Version 9.14(2.10)
Features
The following features are integrated into the Dell EMC Networking 9.14.2 branch through this release:
None
Restrictions
● Prerequisite steps to upgrade the Dell EMC Networking OS from earlier version to 9.14.2.0 or later:
1. Uninstall the older version of the Open Automation (OA) package
2. Upgrade the Dell EMC Networking OS to 9.14.2.0 or later version
3. Install the following OA packages from the respective upgraded version:
a. SmartScripts
b. Puppet
c. Open management infrastructure (OMI)
d. SNMP MIB
Prerequisite steps to downgrade the Dell EMC Networking OS from 9.14.2.0 or later to the earlier version:
1. Uninstall the OA package of 9.14.2.0 or later version
2. Downgrade the Dell EMC Networking OS to an earlier version
3. Install the respective OA package from an earlier version
For more information about installing, uninstalling and upgrading the Dell EMC Networking OS and OA package, refer the
respective Dell EMC System Release Notes.
● If you downgrade the Dell EMC Networking OS version from 9.14.2.10 to 9.11.0.0 or any older versions, the system displays
the following error message even though there is no functional impact:
CDB boot error: C.cdb file format
Before downgrading, save the current configuration and then remove the CDB files (confd_cdb.tar.gz.version and
confd_cdb.tar.gz). To remove the files, use the following steps:
DellEMC#write memory
DellEMC#delete flash://confd_cdb.tar.gz.version
DellEMC#delete flash://confd_cdb.tar.gz
DellEMC#reload
● While deploying the system in the normal-reload mode in BMP configuration, use the ip ssh server enable command
at the beginning of the startup configuration if the write memory command is used at the end of the configuration.
● REST API does not support AAA authentication.
● The following features are not available in the Dell EMC Networking OS from version 9.7(0.0):
○ PIM ECMP
○ Static IGMP join (ip igmp static-group)
○ IGMP querier timeout configuration (ip igmp querier-timeout)
○ IGMP group join limit (ip igmp group join-limit)
● Half-Duplex mode is not supported.
● When FRRP is enabled in a VLT domain, no flavor of Spanning tree should concurrently be enabled on the nodes of that
specific VLT domain. In essence FRRP and xSTP should not co-exist in a VLT environment.
Changes to Default Behavior and CLI Syntax
● From 9.14(2.4P1) onwards, a new nand chip ships on the S3100 series switch. This chip supports the new UBoot version
5.2.1.10.
3