Deployment Guide

Table Of Contents
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.14(1.0) Introduced on the S3048ON, S4048ON, S4048T-ON, and S6010ON.
9.14(0.0) Introduced on the S5048FON, S6100ON, and Z9100ON.
Usage
Information
Although the Dell EMC Networking OS help does not display the corepartition keyword, the
command works if you manually type it.
Example
DellEMC#
DellEMC#fsck corepartittion
% Error: Expect flash device name as input.
DellEMC#fsck corepartition
%% Warning : This command should be given only on Techinical Support
request.
Switch should be rebooted after executing this command.
Do you want to continue [confirm yes/no]: yes
Bad character
Jul 5 03:14:22 %Z9100-ON:1 %KERN-2-INT: wd0: wd_trim_extent success
0
ddb.command: call f10_set_sonic_partition(1) -> call
wd_trim_handler(1447800) > /dev/null 2>&1
DellEMC#Jul 5 03:14:23 %Z9100-ON:1 %KERN-2-INT: wd0: wd_trim_extent
successwd0: wd_trim_extent success
fsck flash
Checks the flash file system for errors.
Syntax
fsck {flash: | usbflash:}
Parameters
flash:
For a directory on the internal Flash, enter flash:// directory name.
usbflash:
For a directory on the external USB flash, enter usbflash:// directory name.
Defaults None
Command Modes EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100-ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
9.1(0.0) Introduced on S4810 and Z9000.
File Management 63