White Papers

Table Of Contents
exec-banner
Enable the display of a text string when the user enters EXEC mode.
Syntax
exec-banner
Defaults Enabled on all lines (if configured, the banner appears).
Command Modes LINE
Supported Modes FullSwitch
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
Optionally, use the banner exec command to create a text string that is displayed when you access
EXEC mode. This command toggles that display.
Related
Commands
banner exec configures a banner to display when entering EXEC mode.
line enables and configures console and virtual terminal lines to the system.
enable optic-info-update interval
Enable polling intervals of optical information updates for simple network management protocol (SNMP).
Syntax
enable optic-info-update interval seconds
To disable optical power information updates, use the no enable optic-info-update interval
command.
Parameters
interval
seconds
Enter the keyword interval then the polling interval in seconds. The range is
from 120 to 6000 seconds. The default is 300 seconds (5 minutes).
Defaults Disabled
Command Modes CONFIGURATION
Supported Modes FullSwitch
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Replaces the enable xfp-power-updates command.
Usage
Information
To enable polling and to configure the polling frequency, use this command.
enable secure
Creates configurable FullSwitch mode where Chassis Management Controller (CMC) access to FN IOM is bypassed for the
elements critical to the security certifications.
Syntax
enable secure
To disable the secure mode, use no enable secure command.
Parameters None
Supported Modes FullSwitch
Control and Monitoring 85