White Papers

Table Of Contents
iscsi profile-compellent
Configure the auto-detection of Dell Compellent arrays on a port.
Syntax
iscsi profile-compellent
Defaults Dell Compellent disk arrays are not detected.
Command Modes INTERFACE
Supported Modes
Programmable-Mux (PMUX)
FullSwitch
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
9.2(0.0) Introduced on the M I/O Aggregator.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
iscsi target port
Configure the iSCSI target ports and optionally, the IP addresses on which iSCSI communication is monitored.
Syntax
iscsi target port [tcp-port-2...tcp-port-16]ip-address [ip-address]
To remove the configured iSCSI target ports or IP addresses, use the no iscsi target port
command.
Parameters
tcp-
port-2...tcpport-
16
Enter the tcp-port number of the iSCSI target ports. The tcp-port-n is the TCP
port number or a list of TCP port numbers on which the iSCSI target listens to
requests. Separate port numbers with a comma. The default is 860, 3260.
ip-address (Optional) Enter the ip-address that the iSCSI monitors. The ip-address specifies
the IP address of the iSCSI target.
Defaults 860, 3260
Command Modes CONFIGURATION
Supported Modes
Programmable-Mux (PMUX)
FullSwitch
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
9.2(0.0) Introduced on the M I/O Aggregator.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module
Usage
Information
You can configure up to 16 target TCP ports on the switch in one command or multiple commands.
When you use the no iscsi target port command and the TCP port you wish to delete is one
bound to a specific IP address, the IP address value must be included in the command.