The interface must be enabled to run the test or an error message is generated:
Related
Commands
show tdr Displays the results of the TDR test.
show tdr
Displays the TDR test results.
Syntax
show tdr interface
Parameters
interface
Enter the keyword TenGigabitEthernet followed by the slot/port information
for the 100/1000/10 GbaseT Ethernet interface.
Defaults none
Command Modes EXEC
Supported Modes All Modes
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Usage
Information
If the TDR test has not been run, an error message is generated:
%Error: Please run the TDR test first
The following describes the TDR test status.
Status Definition
OK Status:
Terminated
TDR test is complete, no fault is detected on the cable, and the test is terminated.
Length: 92
(+/- 1) meters,
Status: Shorted
A short is detected on the cable. The location, in this Example is 92 meters. The
short is accurate to plus or minus one meter.
Length: 93
(+/- 1) meters,
Status: Open
An opening is detected on the cable. The location, in this Example is 93 meters. The
open is accurate to plus or minus one meter.
Status:
Impedance
Mismatch
There is an impedance mismatch in the cables.
Example
Related
Commands
tdr-cable-test Runs the TDR test.