White Papers

Table Of Contents
Field Description
Uptime Displays the age of the port channel in hours:minutes:seconds.
Ports Lists the interfaces assigned to this port channel.
(untitled) Displays the status of the physical interfaces (up or down).
In Layer 2 port channels, an * (asterisk) indicates which interface is the primary
port of the port channel. The primary port sends out interface PDU.
In Layer 3 port channels, the primary port is not indicated.
Example
Dell#show int po bri
Codes: L - LACP Port-channel
O - OpenFlow Controller Port-channel
A - Auto Port-channel
I - Internally Lagged
LAG Mode Status Uptime Ports
L 128 L3 down 00:00:00
Dell#
To indicate the LACP fallback, Internally lagged is added to the list. When the LAG auto-
configures itself, the LAG status describes as I.
Related
Commands
show lacp displays the LACP matrix.
Time Domain Reflectometer (TDR) Commands
TDR is useful for troubleshooting an interface that is not establishing a link; either it is flapping or not coming up at all. TDR
detects open or short conditions of copper cables on 100/1000/10G Base-T modules.
tdr-cable-test
show tdr
Important Points to Remember
The interface and port must be enabled (configuredsee the interface command) before running TDR. An error
message is generated if you have not enabled the interface.
The interface on the far-end device must be shut down before running TDR.
Because TDR is an intrusive test on an interface that is not establishing a link, do not run TDR on an interface that is passing
traffic.
When testing between two devices, do not run the test on both ends of the cable.
tdr-cable-test
Test the condition of copper cables on 100/1000/10GBase-T modules.
Syntax
tdr-cable-test interface
Parameters
interface
Enter the keyword TenGigabitEthernet followed by the slot/port information
for the 100/1000/10GBase-T Ethernet interface.
Defaults none
Command Modes EXEC
Supported Modes All Modes
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
Interfaces 523