White Papers

Table Of Contents
Version Description
9.10(0.0) Introduced on the S6000, S6000ON, S5000, S4810, S4820T, S3048ON,
S4048ON, M I/O Aggregator, FN I/O Module, MXL, C9010, S3100 series, and
Z9100-ON.
Usage
Information
The wavelength can be configured only on a tunable 10Gigabit SFP+ optic. The wavelength range is
from 1528.3 nm to 1568.77nm.
If you configure the wavelength on a non-tunable optic, there is no change to the existing wavelength.
The configured wavelength is saved in the running configuration and is applicable, when a tunable optic is
used.
If you do not configure the wavelength on an inserted tunable optic, the existing wavelength is used.
Example
The following example shows the wavelength set for a tunable 10Gigabit SFP+ optic:
Related
Commands
show config displays the interface configuration.
Port Channel Commands
A Link Aggregation Group (LAG) is a group of links that appear to a MAC client as if they were a single link according to IEEE
802.3ad. In Dell Networking OS, a LAG is referred to as a Port Channel.
For the Aggregator, the maximum port channel ID is 128 and the maximum members per port channel is 4.
Because each port can be assigned to only one Port Channel, and each Port Channel must have at least one port, some of those
nominally available Port Channels might have no function because they could have no members if there are not enough ports
installed.
NOTE:
For information about Dell Networking OS link aggregation control protocol (LACP) for dynamic LAGs, refer to the
Link Aggregation Control Protocol (LACP) chapter. For more information about configuring and using Port Channels, refer
to the Dell PowerEdge FN I/O Aggregator Configuration Guide
channel-member
Add an interface to the Port Channel, while in INTERFACE PORTCHANNEL mode.
Syntax
channel-member interface
To delete an interface from a Port Channel, use the no channel-member interface command.
Parameters
interface
(OPTIONAL) Enter the following keywords and slot/port or number information:
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
Defaults Not configured.
Command Modes INTERFACE PORTCHANNEL
Supported Modes Programmable-Mux (PMUX)
FullSwitch
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
Usage
Information
Use the interface port-channel command to access this command.
You cannot add an interface to a Port Channel if the interface contains an IP address in its configuration.
Interfaces 517