show interfaces transceiver
Display the physical status and operational status of an installed transceiver. The output also displays the transceivers serial
number.
Syntax
show interfaces tengigabitethernet slot/port transceiver
Parameters
tengigabitethern
et
For a 10G interface, enter the keyword tengigabitethernet then the slot/port
information.
NOTE: This command also enables you to view information corresponding to
a range of ports. However, for Open Networking (ON) platforms the notation
for specifying port range in the command is different from how you specify in
non-ON platforms.
For non-ON platforms, you can specify multiple ports as slot/port-
range. For example, if you want to display information corresponding to
all ports between 1 and 4, specify the port range as show interfaces
interface-type 1/1 - 4.
For ON platforms, you can specify multiple ports as slot/port/
[subport] - slot/port/[subpot]. For example, if you want to
display information corresponding to all ports between 1 and 4, specify
the port range as show interfaces interface-type 1/1/1 -
1/4/1.
Command Modes
EXEC
EXEC Privilege
Supported Modes FullSwitch
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM and added support to display the interface
configurations corresponding to a range of ports.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
The following describes the show interfaces transceiver command shown in the following
example.
Line Description
Rx Power
measurement
type
Output depends on the vendor, typically either Average or OMA (Receiver
optical modulation amplitude).
Temp High Alarm
threshold
Factory-defined setting, typically in Centigrade. Value differs between SFPs and
SFP+.
Voltage High
Alarm threshold
Displays the interface index number used by SNMP to identify the interface.
Bias High Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
TX Power High
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power High
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Voltage Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
510 Interfaces