White Papers

Table Of Contents
Command Modes
EXEC
EXEC Privilege
Supported Modes FullSwitch
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.3(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
9.1.1.0 Introduced on the S5000.
Usage
Information
Use the show fcoe-map command to display the FC and FCoE parameters used to configure server-
facing Ethernet (FCoE) and fabric-facing FC ports in all FCoE maps on the switch.
In each FCoE map, the values for the fabric ID and FC-MAP that identify the SAN fabric to which FC
storage traffic is sent, and the FCoE VLAN to be used must be unique.
An FCoE map is used to identify the SAN fabric to which FCoE storage traffic is sent. It also virtualizes
the switch with FC Flex IO module FC ports, so that they appear to downstream server CNA ports as
FCoE Forwarder (FCF) ports on an FCoE network.
Example
Dell#show system stack-unit 0 iom-mode
Unit Boot-Mode Next-Boot
------------------------------------------------
0 standalone standalone
Dell#show fcoe-map
Fabric Name SAN_FABRIC
Fabric Type npiv
Fabric Id 1002
Vlan Id 1002
Vlan priority 3
FC-MAP 0efc00
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State DOWN
=======================================================
Members
Fc 0/9 Fc 0/10
=======================================================
=======================================================
Dell#
Related
Commands
fcoe-map creates an FCoE map which contains the parameters used in the communication between
servers and a SAN fabric.
show system stack-unit port-group portmode
Display the port-group port mode information.
Syntax
show system stack-unit unit-number port-group portmode
Parameters
stack-unit
unit-
number
Enter the keywords stack-unit then the unit number. The range is from 0 to 11.
Command Modes
EXEC
EXEC Privilege
Command
History
Version Description
9.11(0.0) Included support for all external ports.
436 FC FLEXIO FPORT