White Papers

Table Of Contents
Example
Dell(conf)# fcoe-map default_full_fabric
Dell(conf-fcoe-default_full_fabric)# fc-fabric
Dell(conf-fmap-default_full_fabric-fcfabric)# active-zoneset zs1
Related
Commands
show fc zoneset displays the configured and active zoneset.
stack-unit port-group port portmode
Convert the external ports to Fibre Channel or Ethernet mode.
Syntax
stack-unit unit number port-group 0-1 port 9-12 portmode {ethernet | fc}
Parameters
stack-unit Enter the keywords stack-unit then the stack member number to select the
stack unit. The range is from 0 to 5.
port-group Enter the keywords port-group then the port group number. The range is from 0
to 1.
port Enter the keyword port then the port number. The range is from 9 to 12. The
port numbers 9 to 10 map to port-group 0 and the port numbers 11 to 12 map to
port-group 1.
portmode Enter the keyword portmode to set the port mode. The options are:
ethernet convert to Ethernet mode.
fc convert to Fibre Channel mode.
Defaults
Ports 9, 10 Fibre Channel mode
Ports 11, 12 Ethernet mode
Command Modes CONFIGURATION
Supported Modes All Modes
Command
History
Version Description
9.11(0.0) Included support for all external ports.
9.6(0.0) Supported on the FN2210S Aggregator.
Related
Commands
show system stack-unit port-group portmode displays the port-group port mode information.
show fc ns
Display the devices in the name server database.
Syntax
show fc ns { switch } [brief]
Parameters
switch
Enter the keyword switch to display all the devices in the name server database
of the switch.
brief
Enter the keyword brief to display in brief devices in the name server database.
Command Modes
EXEC
EXEC Privilege
Supported Modes FullSwitch
FC FLEXIO FPORT 431