ipv6 ospf bfd all-neighbors
Establish BFD sessions with all OSPFv3 neighbors on a single interface or use non-default BFD session parameters.
Syntax
ipv6 ospf bfd all-neighbors [disable | [interval interval min_rx min_rx
multiplier value role {active | passive}]]
To disable all BFD sessions on an OSPFv3 interface implicitly, use the no ipv6 ospf bfd all-
neighbors [disable | [interval interval min_rx min_rx multiplier value role
{active | passive}]]command in interface mode..
Parameters
disable (OPTIONAL) Enter the keyword disable to disable BFD on this interface.
interval
milliseconds
(OPTIONAL) Enter the keyword interval to specify non-default BFD session
parameters beginning with the transmission interval. The range is from 50 to 1000.
The default is 200.
min_rx
milliseconds
Enter the keywords min_rx to specify the minimum rate at which the local system
receives control packets from the remote system. The range is from 50 to 1000.
The default is 200.
multiplier
value
Enter the keyword multiplier to specify the number of packets that must be
missed in order to declare a session down. The range is from 3 to 50. The default is
3.
role [active |
passive]
Enter the role that the local system assumes:
Active The active system initiates the BFD session. Both systems can be
active for the same session.
Passive The passive system does not initiate a session. It only responds to
a request for session initialization from the active system.
The default is Active.
Defaults See Parameters
Command Modes INTERFACE
Supported Modes FullSwitch
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
isis bfd all-neighbors
Enable BFD on all IS-IS neighbors discovered on an interface.
Syntax
isis bfd all-neighbors [disable | [interval interval min_rx min_rx
multiplier value role {active | passive}]]
To remove all BFD sessions with IS-IS neighbors discovered on this interface, use the no isis bfd
all-neighbors [disable | [interval interval min_rx min_rx multiplier value
role {active | passive}]] command.
Parameters
disable (OPTIONAL) Enter the keyword disable to disable BFD on this interface.
interval
milliseconds
(OPTIONAL) Enter the keywords interval to specify non-default BFD session
parameters beginning with the transmission interval. The range is from 50 to 1000.
The default is 200.
min_rx
milliseconds
Enter the keywords min_rx to specify the minimum rate at which the local system
would like to receive control packets from the remote system. The range is from 50
to 1000. The default is 200.
Bidirectional Forwarding Detection (BFD) 255