White Papers

Table Of Contents
sflow polling-interval (Interface)
Set the sFlow polling interval at an interface (overrides the global-level setting).
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval command.
Parameters
interval value
Enter the interval value in seconds. The range is from 15 to 86400 seconds. The
default is the global counter polling interval.
Defaults The same value as the current global default counter polling interval.
Command Modes INTERFACE
Supported Modes FullSwitch Mode
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
This command sets the counter polling interval for an interface.
Related
Commands
sflow polling-interval (Global) globally sets the polling interval.
sflow sample-rate (Global)
Change the global default sampling rate.
Syntax
sflow sample-rate value
To return to the default sampling rate, use the no sflow sample-rate command.
Parameters
value
Enter the sampling rate value. The range is from 256 to 8388608 packets. Enter
values in powers of 2 only; for example, 4096, 8192, 16384, and so on. The default
is 32768 packets.
Defaults 32768 packets
Command Modes CONFIGURATION
Supported Modes FullSwitch Mode
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
Sample-rate is the average number of packets skipped before the sample is taken. This command
changes the global default sampling rate. You can configure an interface to use a different sampling rate
than the global sampling rate. If the value entered is not a correct power of 2, the command generates an
error message with the previous and next power of 2 value. Select one of these two packet numbers and
re-enter the command.
Related
Commands
sflow sample-rate (Interface) changes the interface sampling rate.
sFlow 1075