White Papers

Table Of Contents
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm) Power Usage (W)
-----------------------------------------------------------------------------
0 0 up AC up 19264 290.0
0 1 up AC up 19104 288.5
0 2 up AC up 19072 288.5
0 3 up AC up 19328 324.0
Total power: 1191.0 W
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------------------------------
0 0 up up 6581 up 6614
0 1 up up 6542 up 6603
0 2 up up 6548 up 6704
0 3 up up 6642 up 6619
0 4 up up 6581 up 6642
Speed in RPM
Example of Running Offline Diagnostics on a Standalone Switch
Dell# diag system unit
Warning - diagnostic execution will cause multiple link flaps on the peer side -
advisable to shut directly connected ports
Proceed with Diags [confirm yes/no]: yes
FTOS-BMP#00:11:05: %Z9500LC12:1 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on linecard 1
00:11:05 : Approximate time to complete the Diags (all levels)... 10 Mins
00:11:05: %Z9500LC12:0 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on linecard 0
00:11:05 : Approximate time to complete the Diags (all levels)... 10 Mins
00:11:06: %Z9500LC12:2 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on linecard 2
00:11:06 : Approximate time to complete the Diags (all levels)... 10 Mins
00:11:06: %SYSTEM:LP %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on CP unit
00:11:06 : Approximate time to complete the Diags (all levels)... 10 Mins
00:13:17 : Diagnostic test results are stored on file: flash:/TestReport-LP-0.txt
00:13:19 : Diagnostic test results are stored on file: flash:/TestReport-LP-1.txt
00:13:20 : Diagnostic test results are stored on file: flash:/TestReport-LP-2.txt
00:13:22: %Z9500LC12:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on linecard 0
00:13:22 : Recommended to reboot the system after diagnostics!!!
00:13:24: %Z9500LC12:1 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on linecard 1
00:13:25 : Recommended to reboot the system after diagnostics!!!
00:13:25: %Z9500LC12:2 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on linecard 2
00:13:25 : Recommended to reboot the system after diagnostics!!!
00:15:41 : Diagnostic test results are stored on file: flash:/TestReport-CP-unit.txt
00:15:46: %SYSTEM:LP %DIAGAGT-6-DA_DIAG_DONE: Diags finished on CP unit
00:15:47 : Recommended to reboot the system after diagnostics!!!
Dell# dir
Directory of flash:
1 drwx 4096 Jan 01 1980 00:00:00 +00:00 .
2 drwx 2048 Mar 06 2014 10:31:40 +00:00 ..
3 drwx 4096 Apr 13 2008 14:26:18 +00:00 TRACE_LOG_DIR
4 drwx 4096 Apr 13 2008 14:26:18 +00:00 CRASH_LOG_DIR
5 drwx 4096 Apr 13 2008 14:26:18 +00:00 CORE_DUMP_DIR
6 d--- 4096 Apr 13 2008 14:26:18 +00:00 ADMIN_DIR
7 -rwx 3 Mar 06 2014 10:42:42 +00:00 ssMDiskUsageInfo
8 -rwx 91459902 Apr 13 2008 14:38:32 +00:00 rain-9.2.1.0B1
9 -rwx 6127 Mar 06 2014 10:12:06 +00:00 startup-config
10 drwx 4096 Apr 13 2008 14:43:14 +00:00 NVTRACE_LOG_DIR
11 drwx 4096 Apr 13 2008 14:43:14 +00:00 RUNTIME_PATCH_DIR
12 -rwx 32 Mar 06 2014 10:18:32 +00:00 ssCronCopy.txt
13 drwx 4096 Apr 13 2008 14:45:54 +00:00 CONFD_LOG_DIR
14 -rwx 96573311 Apr 13 2008 14:54:24 +00:00 rain500
15 -rwx 40 Apr 30 2008 15:04:30 +00:00 dhcpBindConflict
16 -rwx 5398 Apr 20 2008 09:14:58 +00:00 without-copp
17 -rwx 9716 Apr 22 2008 14:11:34 +00:00 PR
18 -rwx 4568 Mar 06 2014 02:10:34 +00:00 BMP-runningCfgCpy
Debugging and Diagnostics
273