White Papers

Table Of Contents
LEVEL 1 DIAGNOSTIC
eepromTest .................................................. PASS
i2cTest ..................................................... PASS
macPhyRegTest ............................................... PASS
Starting test: partyLinkStatusTest ......
WM0 Link Status UP
partyLinkStatusTest ......................................... PASS
Starting test: portcardHiGigLinkStatusTest ......
+ HG Link Status Test for Unit 0 (Portcard 0): PASSED
+ HG Link Status Test for Unit 1 (Portcard 1): PASSED
+ HG Link Status Test for Unit 2 (Portcard 2): PASSED
portcardHiGigLinkStatusTest ................................. PASS
Starting test: portcardXELinkStatusTest ......
+ XE Link Status Test for unit 0 (Portcard 0): PASSED
+ XE Link Status Test for unit 1 (Portcard 1): PASSED
ERROR: Unit 2 (Portcard 2): XE 11 is DOWN
+ XE Link Status Test for unit 2 (Portcard 2): FAILED
portcardXELinkStatusTest .................................... FAIL
qsfpOpticsTest .............................................. PASS
qsfpPhyTest ................................................. PASS
qsfpPresenceTest ............................................ PASS
rtcTest ..................................................... PASS
sataSsdTest ................................................. PASS
--------- Group Test Statistics ---------
Total : 22
Passed : 21
Failed : 1
Elapsed time : 00H:00M:56S
Stop reason : after completion
------ Failed tests (level, times) ------
portcardXELinkStatusTest (1, 1)
-------------------------------------------------------------------
Examples of Running Offline Diagnostics
Example of Taking a Switch Offline
Dell# offline system
Warning - offline of system will bring down all the protocols and
the system will be operationally down, except for running Diagnostics.
The "reload" command is required for normal operation after the offline command is
issued.
Proceed with Offline [confirm yes/no]:yes
00:10:29: %SYSTEM:CP %CHMGR-2-UNIT_DOWN: linecard 0 down - linecard offline
FTOS-BMP#00:10:30: %SYSTEM:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo 0/4
00:10:30: %SYSTEM:CP %IFMGR-1-DEL_PORT: Removed port: Fo 0/0-44,
00:10:30: %SYSTEM:CP %CHMGR-2-UNIT_DOWN: linecard 1 down - linecard offline
00:10:30: %SYSTEM:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo 1/0
00:10:30: %SYSTEM:CP %IFMGR-1-DEL_PORT: Removed port: Fo 1/0-44,
00:10:30: %SYSTEM:CP %CHMGR-2-UNIT_DOWN: linecard 2 down - linecard offline
00:10:30: %SYSTEM:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo 2/0
00:10:30: %SYSTEM:CP %IFMGR-1-DEL_PORT: Removed port: Fo 2/0-44,
00:10:31: %SYSTEM:CP %CHMGR-2-UNIT_DOWN: CP unit down - CP unit offline
Example of Verifying the Offline/Online Status of a Switch
Dell# show system brief
Stack MAC : 74:86:7a:ff:70:74
Reload-Type : normal-reload [Next boot : normal-reload]
-- Linecard Info --
LinecardId Type Status ReqTyp CurTyp Version Ports
----------------------------------------------------------------------------------------
0 Linecard offline Z9500LC36 Z9500LC36 9.2(1.0B2) 144
1 Linecard offline Z9500LC48 Z9500LC48 9.2(1.0B2) 192
2 Linecard offline Z9500LC48 Z9500LC48 9.2(1.0B2) 192
272