White Papers

Table Of Contents
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.12(0.0) Added the keyword ipv4mirracl.
9.11(0.0) Added the keyword ipv4udfmirracl.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100-ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Added the nlbcluster ACL keyword. Introduced on the S6000-ON.
9.4.(0.0) Added support for PBR and VRF.
9.2(1.0) Introduced on the Z9500.
9.2(0.2) Added support for fcoe.
9.1.(0.0) Added support for OpenFlow.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.10.2 Clarified block information for the S4810.
8.3.10.0 Introduced on the S4810.
8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos.
8.2.1.0 Introduced on the S-Series.
7.8.1.0 Introduced on the C-Series.
Usage
Information
Save the new CAM settings to the startup-config (write-mem or copy run start) then reload the
system for the new settings to take effect.
The total amount of space allowed is 16 FP Blocks. System flow requires three blocks; these blocks
cannot be reallocated. Only number of blocks can be configured by the user .
The ipv6acl allocation must be a factor of 2.
If allocation values are not entered for the CAM regions, the value is 0.
If you enable BMP, to perform a reload on the chassis to upgrade any configuration changes that have
changed the NVRAM content, use the command reload conditional nvram-cfg-change.
cam-audit linecard
Enable audit of the IPv4 forwarding table on all line cards.
Syntax
cam-audit linecard all ipv4-fib interval time-in-minutes
Parameters
all Enter the keyword all to enable CAM audit on all line cards.
ipv4-fib Enter the keyword ipv4-fib to designate the CAM audit on the IPv4 forwarding
entries.
interval
time-in-
minutes
Enter the keyword interval followed by the frequency in minutes of the CAM
audit. Range: 5 to 1440 minutes (24 hours). Default: 60 minutes.
Control and Monitoring 85