When you configure keepalive, the system sends a self-addressed packet out of the configured
interface to verify that the far end of a WAN link is up. When you configure no keepalive, the system
does not send keepalive packets and so the local end of a WAN link remains up even if the remote end is
down.
linecard portmode
Split a single 40G port into four 10G ports on the switch.
Syntax
linecard slot-id port number portmode quad
Parameters
linecard
slot-id
Enter the slot ID of a Z9500 line card to reset. The range of slot IDs is from 0 to 2.
number
Enter the port number of the 40G port to be split. A 40G port number is a multiple
of 4; for example, 0, 4, 8, 12, ... 120, 124, 128).
Defaults Disabled.
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
Usage
Information
Enabling quad mode on a port removes the interface configurations (if any) on the port after a save and
reload. Be sure that the port is removed from other L2 and L3 feature configurations.
You must save and reload the system for the 40G to 4x10G port change to take effect.
This command cannot be used if LR4 optics are inserted in the 40G port.
monitor interface
Monitor counters on a single interface or all interfaces. The screen is refreshed every five seconds and the CLI prompt
disappears.
Syntax
monitor interface [interface] [linecard slot-id]
To disable monitoring and return to the CLI prompt, press the q key.
Parameters
interface
(OPTIONAL) Enter the following keywords and the interface information:
For the Management interface on the stack-unit, enter the keyword
managementEthernet then the slot/port information.
For a port channel interface, enter the keyword port-channel and then a
number.
For a Tunnel interface, enter the keyword tunnel then the slot/port. The
range is from 1 to 16383.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
linecard
slot-id
Enter the linecard slot-id parameters to specify the Z9500 ports on a line
card. The range of slot IDs is from 0 to 2.
Command Modes
EXEC
EXEC Privilege
714 Interfaces