White Papers

Table Of Contents
Linecard slot 1: No card diags executed yet (Card Offline).
Linecard slot 2: No card diags executed yet (Card Offline).
Linecard slot 3: No card diags executed yet (Card Offline).
-------------------------------------------------------------------
Example:
After offline
diagnostics are
run on a switch
Dell# show diag information
Diag information:
Diag software image version:
9-2(1-509)
-------------------------------------------------------------------
Linecard slot 0: Card diags are done (Card Offline).
Linecard slot 1: Card diags are done (Card Offline).
Linecard slot 2: Card diags are done (Card Offline).
Linecard slot 3: Card diags are done (Card Offline).
-------------------------------------------------------------------
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version 9.2(1.0) Introduced on the Z9500.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced the verbose option.
Version 7.7.1.0 Introduced on the S-Series.
show diag testcase
Display the offline diagnostic tests available for the Z9500 CPUs at each level.
Syntax
show diag testcase {all | {{cp | rp | linecard} unit-id} [alllevels |
level0 | level1 | level2]
Parameters
all Enter the keyword all to display the complete suite of offline diagnostic tests
available on the Z9500.
cp
unit-id
Enter the cp unit-id parameters to display only the offline diagnostic tests
available on the Control Processor CPU. The Control Processor CPU ID is 0.
rp
unit-id
Enter the rp unit-id parameters to display only the offline diagnostic tests
available on the Route Processor CPU. The Route Processor CPU ID is 0.
linecard
unit-id
Enter the linecard unit-id parameters to display only the offline diagnostic
tests available for a specified line card. The range of line-card CPU IDs is from 0 to
2. Each line-card CPU processes packets on the corresponding Z9500 line card; for
example, line-card CPU 1 processes packets on line card 1.
alllevels Enter the keyword alllevels to display the the complete set of offline
diagnostic tests.
level0 Enter the keyword level0 to display only the Level 0 diagnostic tests. Level 0
diagnostics check for the presence of various components and perform essential
path verifications. In addition, they verify the identification registers of the
components on the board.
level1 Enter the keyword Level1 to display only the Level 1 diagnostic tests. Level
1 diagnostics is a smaller set of diagnostic tests with support for automatic
partitioning. They perform status/self test for all the components on the board and
test their registers for appropriate values. In addition, they perform extensive tests
on memory devices (for example, SDRAM, flash, NVRAM, EEPROM, and CPLD)
538 Debugging and Diagnostics