White Papers

Table Of Contents
ERROR: Qsfp Module:28 is not present
ERROR: Qsfp Module:29 is not present
qsfpOpticsTest .............................................. FAIL
qsfpPhyTest ................................................. PASS
rtcTest ..................................................... PASS
sataSsdTest ................................................. PASS
Starting test: temperatureTest ......
Thermal Monitor Diodes:
Diode[0] temperature 38.0 C
Diode[1] temperature 39.4 C
Diode[2] temperature 39.1 C
Diode[4] temperature 38.9 C
Port card[0]:
Average temperature 50.2 C, maximum 53.6 C
Port card[1]:
Average temperature 48.7 C, maximum 51.4 C
Port card[2]:
Average temperature 48.8 C, maximum 50.9 C
Ethernet MAC temperature 50.0 C
temperatureTest ............................................. PASS
--------- Group Test Statistics ---------
Total : 11
Passed : 9
Failed : 2
Elapsed time : 00H:00M:18S
Stop reason : after completion
------ Failed tests (level, times) ------
i2cTest (0, 1)
qsfpOpticsTest (0, 1)
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version 9.2(1.0) Introduced on the Z9500.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced the verbose option.
Version 7.7.1.0 Introduced on the S-Series.
show diag information
Display the status of offline diagnostic tests on a switch.
Syntax
show diag information
Defaults None.
Command Modes EXEC Privilege
Usage
Information
Use the show diag information command to view the progress of offline diagnostics on Z9500
CPUs: line-card processors (Linecard slots 0 to 2), Control Processor (Linecard slot 3), and Route
Processor (Linecard slot 4).
Example:
Before offline
diagnostics are
run on a switch
Dell# show diag information
Diag information:
Diag software image version:
9-2(1-509)
-------------------------------------------------------------------
Linecard slot 0: No card diags executed yet (Card Offline).
Debugging and Diagnostics 537