White Papers

Table Of Contents
testname
name
Enter the testname name parameters to run a specified offline diagnostic test.
Enclose the test-case name in double quotes ( ). For example: diag level1
testname first.
terminate Enter the keyword terminate to stop the offline diagnostic tests that are
running.
Defaults All offline diagnostic tests are run on all Z9500 CPUs (Control Processor, Route Processor, and line
cards).
Command Modes EXEC Privilege
Usage
Information
Before you use this command to run diagnostic test, make sure the switch is offline (offline system
command).
You are prompted to reboot when the off-line diagnostics complete.
Use the show diag command to view a summary of diagnostic information presented for each Z9500
CPU.
At the end of offline diagnostic tests, a test report is generated. The filename of the report is TestReport-
{CP/LP/RP}-N.txt, where {CP/LP/RP}-N identifies the CPU and CPU ID on which the diagnostics were
run: Route Processor 0, Control Processor 0 or a line-card CPU {02}. The report is stored at flash://
and ramdisk:/diagnostic. To view the test report, use the show file flash://filenamecommand.
A sample filename is TestReport-LP-2.
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version 9.2(1.0) Introduced on the Z9500.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced the verbose option.
Version 7.7.1.0 Introduced on the S-Series.
Related
Commands
offline stack-unit bring a switch offline to run diagnostic tests.
online stack-unit reload the system after running offline diagnostic tests.
offline stack-unit
Place a stack unit in the offline state.
Syntax
offline stack-unit number
Parameters
number
Enter the stack-unit id.
Defaults None
Command Modes EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
532 Debugging and Diagnostics