White Papers

Table Of Contents
Related
Commands
util-threshold mem Configure memory utilization thresholds.
util-threshold cpu Configure CPU utilization thresholds.
system location-led
Toggle the location LED of the chassis and (optionally) the location LED of a specified Z9500 port on or off.
Syntax
system location-led [interface {fortyGigE | tengigabitethernet} slot/port]
{on | off}
Parameters
interface
{fortyGigE |
tengigabitethern
et}
Specify the port type: 40-Gigabit Ethernet or 10-Gigabit Ethernet.
slot
/
port
Enter the slot and port number. The range of Z9500 slot numbers is 0 to 2.
on |off Turn the location LEDs of the chassis and a specified port on or off.
Defaults The location LEDs of the chassis and Z9500 ports are turned off.
Command Modes EXEC
Command
History
Version Description
9.2(1.0) Introduced on the Z9500.
8.2.1.0 Introduced on the E-Series ExaScale.
Usage
Information
Use the system location-led command to locate the chassis and (optionally) a port on the I/O side
of the Z9500 chassis. The location LED setting is not saved through power cycles.
telnet
Connect through Telnet to a server. The Telnet client and server in Dell EMC Networking support IPv4 and IPv6 connections.
You can establish a Telnet session directly to the router or a connection can be initiated from the router.
NOTE:
The Telnet server and client are VRF-aware. Using the vrf parameter in this command, you can make a Telnet
server or client to listen to a specific VRF. This capability enables a Telent server or client to look up the correct routing
table and establish a connection.
Syntax
telnet {host | ip-address | ipv6-address prefix-length | vrf vrf instance
name} [/source-interface]
Parameters
host Enter the name of a server.
ip-address
Enter the IPv4 address in dotted decimal format of the server.
ipv6-address
prefix-length
Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x
format. The range is from /0 to /128.
NOTE: The :: notation specifies successive hexadecimal fields of zeros.
vrf instance
(Optional) Enter the keyword vrf then the VRF instance name.
source-interface (OPTIONAL) Enter the keywords /source-interface then the interface
information to include the source interface. Enter the following keywords and the
interface information:
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
152 Control and Monitoring