White Papers

Table Of Contents
You can configure up to 128 source ports in a monitoring session. Only one destination port is supported in a monitoring session.
The platform supports multiple source-destination statements in a single monitor session.
The maximum number of source ports that can be supported in a session is 128.
The maximum number of destination ports that can be supported depends on the port mirroring directions as follows:
4 per port pipe, if the four destination ports mirror in one direction, either rx or tx.
2 per port pipe, if the two destination ports mirror in bidirection.
3 per port pipe, if one of the destination port mirrors bidirection and the other two ports mirror in one direction (either rx or
tx).
In the following examples, ports 1/13, 1/14, 1/15, and 1/16 all belong to the same port-pipe. They are pointing to four different
destinations (1/1, 1/2, 1/3, and 1/37). Now it is not possible for another source port from the same port-pipe (for example, 1/17)
to point to another new destination (for example, 1/4). If you attempt to configure another destination (to create 5 MG port),
this message displays: % Error will be thrown in case of RPM and ERPM features.
In the following examples, ports 1/13, 1/14, 1/15, and 1/16 all belong to the same port-pipe. They are pointing to four different
destinations (1/1, 1/2, 1/3, and 1/37). Now it is not possible for another source port from the same port-pipe (for example, 1/17)
to point to another new destination (for example, 1/4). If you attempt to configure another destination (to create 5 MG port),
this message displays: % Error will be thrown in case of RPM and ERPM features.
Example of Changing the Destination Port in a Monitoring Session
DellEMC(conf-mon-sess-5)#do show moni session
SessID Source Destination Dir Mode Source IP Dest IP DSCP
TTL Drop Rate Gre-Protocol FcMonitor
------ ------ ----------- --- ---- --------- -------- ----
--- ---- ---- ----------- ---------
1 Te 1/1 Te 2/1 both Port N/A N/A 0
0 No N/A N/A yes
2 Te 1/1 Te 2/2 both Port N/A N/A 0
0 No N/A N/A yes
3 Te 1/1 Te 2/3 both Port N/A N/A 0
0 No N/A N/A yes
4 Te 1/1 Te 2/4 both Port N/A N/A 0
0 No N/A N/A yes
5 Te 1/1 Te 2/5 both Port N/A N/A 0
0 No N/A N/A yes
DellEMC(conf-mon-sess-5)#
DellEMC(conf)#mon ses 300
DellEMC(conf-mon-sess-300)#source tengig 1/17 destination tengig 1/4 direction tx
% Error: Exceeding max MG ports for this MD port pipe.
DellEMC(conf-mon-sess-300)#
DellEMC(conf-mon-sess-300)#source tengig 1/17 destination tengig 1/1 direction tx
DellEMC(conf-mon-sess-300)#do show mon session
SessID Source Destination Dir Mode Source IP Dest IP DSCP
TTL Drop Rate Gre-Protocol FcMonitor
------ ------ ----------- --- ---- --------- -------- ----
--- ---- ---- ----------- ---------
0 Te 1/13 Te 2/1 rx interface 0.0.0.0 0.0.0.0 0
0 No N/A N/A yes
10 Te 1/14 Te 2/2 rx interface 0.0.0.0 0.0.0.0 0
0 No N/A N/A yes
20 Te 1/15 Te 2/3 rx interface 0.0.0.0 0.0.0.0 0
0 No N/A N/A yes
30 Te 1/16 Te 2/7 rx interface 0.0.0.0 0.0.0.0 0
0 No N/A N/A yes
300 Te 1/17 Te 1/1 rx interface 0.0.0.0 0.0.0.0 0
0 No N/A N/A yes
DellEMC#
Example of Configuring Another Monitoring Session with a Previously Used Destination Port
DellEMC(conf)#monitor session 300
DellEMC(conf-mon-sess-300)#source TenGig 1/17 destination TenGig 1/4 direction tx
% Error: Exceeding max MG ports for this MD port pipe.
DellEMC(conf-mon-sess-300)#
DellEMC(conf-mon-sess-300)#source TenGig 1/17 destination TenGig 1/1 direction tx
DellEMC(conf-mon-sess-300)#do show mon session
SessID Source Destination Dir Mode Source IP Dest IP DSCP
Port Monitoring
651