White Papers

Table Of Contents
NPIV Proxy Gateway
The N-port identifier virtualization (NPIV) proxy gateway (NPG) provides FCoE-FC bridging capability on the S5000 switch.
This chapter describes how to configure and use an NPIV proxy gateway on an S5000 switch in a storage area network (SAN).
Topics:
Benefits of an NPIV Proxy Gateway
NPIV Proxy Gateway Operation
Configure an NPIV Proxy Gateway
Display NPIV Proxy Gateway Information
Benefits of an NPIV Proxy Gateway
The S5000 functions as a top-of-rack edge switch that supports Converged Enhanced Ethernet (CEE) traffic FCoE for
storage, Inter-process Communication (IPC) for servers, and Ethernet LAN (IP cloud) for data as well as Fibre Channel (FC)
links to one or more SAN fabrics.
Using an NPIV proxy gateway (NPG) helps resolve the following problems in a storage area network:
Fibre Channel storage networks typically consist of servers connected to edge switches, which are connected to SAN core
switches. As the SAN grows, it is necessary to add more ports and SAN switches. This results in an increase in the required
domain IDs, which may surpass the upper limit of 239 domain IDs supported in the SAN network. An NPG avoids the need
for additional domain IDs because it is deployed outside the SAN and uses the domain IDs of core switches in its FCoE links.
Fibre Channel storage networks typically consist of servers connected to edge switches, which are connected to SAN core
switches. As the SAN grows, it is necessary to add more ports and SAN switches. This results in an increase in the required
domain IDs, which may surpass the upper limit of 239 domain IDs supported in the SAN network. An NPG avoids the need
for additional domain IDs because it is deployed outside the SAN and uses the domain IDs of core switches in its FCoE links.
NPIV Proxy Gateway Operation
An S5000 configured as an NPG does not join a SAN fabric, but functions as an FCoE-FC bridge that forwards storage traffic
between servers and core SAN switches. The core switches forward SAN traffic to and from FC storage arrays.
The following illustration shows an example of the NPG operation.
37
NPIV Proxy Gateway 561