You can configure whether iSCSI frames are re-marked to contain the configured VLAN priority tag or IP DSCP when forwarded
through the switch.
NOTE: On a switch in which a large proportion of traffic is iSCSI, CoS queue assignments may interfere with other network
control-plane traffic, such as ARP or LACP. Balance preferential treatment of iSCSI traffic against the needs of other
critical data in the network.
Information Monitored in iSCSI Traffic Flows
iSCSI optimization examines the following data in packets and uses the data to track the session and create the classifier entries
that enable QoS treatment.
Initiators IP Address
Targets IP Address
ISID (Initiator defined session identifier)
Initiators IQN (iSCSI qualified name)
Targets IQN
Initiators TCP Port
Targets TCP Port
Connection ID
Aging
Up Time
If no iSCSI traffic is detected for a session during a user-configurable aging period, the session data is cleared.
If more than 256 simultaneous sessions are logged continuously, the following message displays indicating the queue rate limit
has been reached:
%STKUNIT2-M:CP %iSCSI-5-ISCSI_OPT_MAX_SESS_EXCEEDED: New iSCSI Session Ignored: ISID -
400001370000 InitiatorName - iqn.1991-05.com.microsoft:dt-brcd-cna-2 TargetName -
iqn.2001-05.com.equallogic:4-52aed6-b90d9446c-162466364804fa49-wj-v1 TSIH - 0"
Detection and Auto-Configuration for Dell EqualLogic Arrays
The iSCSI optimization feature includes auto-provisioning support with the ability to detect directly connected Dell EqualLogic
storage arrays and automatically reconfigure the switch to enhance storage traffic flows.
The switch uses the link layer discovery protocol (LLDP) to discover Dell EqualLogic devices on the network. LLDP is enabled by
default. For more information about LLDP, refer to Link Aggregation Control Protocol (LACP).
The following message displays the first time a Dell EqualLogic array is detected and describes the configuration changes that
are automatically performed:
%STKUNIT0-M:CP %IFMGR-5-IFM_ISCSI_AUTO_CONFIG: This switch is being configured for
optimal
conditions to support iSCSI traffic which will cause some automatic configuration to
occur
including jumbo frames and flow-control on all ports; no storm control and spanning-tree
port
fast to be enabled on the port of detection.
The following syslog message is generated the first time an EqualLogic array is detected:
%STKUNIT0-M:CP %LLDP-5-LLDP_EQL_DETECTED: EqualLogic Storage Array detected on interface
Te 1/
43
At the first detection of an EqualLogic array, an MTU of 12000 is enabled on all ports and port-channels (if it has not already
been enabled).
Spanning-tree portfast is enabled on the interface LLDP identifies.
Unicast storm control is disabled on the interface LLDP identifies.