show hardware stack-unit {0-11} unit {0-0} details
Execute a specified bShell command from the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} execute-shell-cmd {command}
View the Multicast IPMC replication table from the bShell.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} ipmc-replication
View the internal statistics for each port-pipe (unit) on per port basis.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} port-stats [detail]
View the stack-unit internal registers for each port-pipe.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} register
View the tables from the bShell through the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} table-dump {table name}
Enabling Environmental Monitoring
The S5000 components use environmental monitoring hardware to detect transmit power readings, receive power readings, and
temperature updates.
To receive periodic power updates, you must enable the following command.
Enable environmental monitoring.
enable optic-info-update interval
Dell#show int tengig 0/1 transceiver
SFP is present
SFP+ 1 Serial Base ID fields
SFP+ 1 Id = 0x03
SFP+ 1 Ext Id = 0x04
SFP+ 1 Connector = 0x07
SFP+ 1 Transceiver Code = 0x10 0x00 0x00 0x00 0x00 0x00 0x00 0x00
SFP+ 1 Encoding = 0x06
SFP+ 1 BR Nominal = 0x67
SFP+ 1 Length(SFM) Km = 0x00
SFP+ 1 Length(OM3) 2m = 0x00
SFP+ 1 Length(OM2) 1m = 0x08
SFP+ 1 Length(OM1) 1m = 0x03
SFP+ 1 Length(Copper) 1m = 0x00
SFP+ 1 Vendor Rev = A
SFP+ 1 Laser Wavelength = 850 nm
SFP+ 1 CheckCodeBase = 0x9e
SFP+ 1 Serial Extended ID fields
SFP+ 1 Options = 0x00 0x1a
SFP+ 1 BR max = 0
SFP+ 1 BR min = 0
SFP+ 1 Vendor SN = AL30LGT
SFP+ 1 Datecode = 110715
SFP+ 1 CheckCodeExt = 0xdb
SFP+ 1 Diagnostic Information
===================================
SFP+ 1 Rx Power measurement type = Average
===================================
SFP+ 1 Temp High Alarm threshold = 78.000C
SFP+ 1 Voltage High Alarm threshold = 3.700V
SFP+ 1 Bias High Alarm threshold = 11.800mA
SFP+ 1 TX Power High Alarm threshold = 0.832mW
SFP+ 1 RX Power High Alarm threshold = 1.000mW
SFP+ 1 Temp Low Alarm threshold = -13.000C
SFP+ 1 Voltage Low Alarm threshold = 2.900V