White Papers

Table Of Contents
**********************************S-Series Diagnostics********************
Stack Unit Board Serial Number : DL267160098
CPU Version : MPC8541, Version: 1.1
PLD Version : 5
Diag image based on build : E_MAIN4.7.7.206
Stack Unit Board Voltage levels - 3.300000 V, 2.500000 V, 1.800000 V, 1.250000 V,
1.200000
V, 2.000000 V
Stack Unit Board temperature : 26 Degree C
Stack Unit Number : 0
****************************Stack Unit EEPROM INFO*******************************
********MFG INFO*******************
Data in Chassis Eeprom Mfg Info is listed as...
Vendor Id: 07
Country Code: 01
Date Code: 12172007
Serial Number: DL267160098
Part Number: 7590003600
Product Revision: B
Product Order Number: ${
**************************** LEVEL 0 DIAGNOSTICS**************************
Test 0 - CPLD Presence Test ......................................... PASS
Hardware PCB Revision is - Revision B
Test 1 - CPLD Hardware PCB Revision Test ............................ PASS
Test 2.000 - CPLD Fan-0 Presence Test ............................... PASS
Test 2.001 - CPLD Fan-1 Presence Test ............................... PASS
Test 2.002 - CPLD Fan-2 Presence Test ............................... PASS
Test 2.003 - CPLD Fan-3 Presence Test ............................... PASS
Test 2.004 - CPLD Fan-4 Presence Test ............................... PASS
Test 2.005 - CPLD Fan-5 Presence Test ............................... PASS
Test 3.000 - CPLD Power Bay-0 Presence Test ......................... PASS
Test 3.001 - CPLD Power Bay-1 Presence Test ......................... NOT PRESENT
Test 4 - SDRAM Access Test .......................................... PASS
Test 5 - CPU Access Test ............................................ PASS
Test 6 - I2C Temp Access Test CPU Board ............................. PASS
Test 7 - I2C Temp Access Test Main Board ............................ PASS
Test 8 - RTC Access Test ............................................ PASS
--More--
Trace Logs
In addition to the syslog buffer, Dell Networking OS buffers trace messages which are continuously written by various Dell
Networking OS software tasks to report hardware and software events and status information.
Each trace message provides the date, time, and name of the Dell Networking OS process. All messages are stored in a ring
buffer. You can save the messages to a file either manually or automatically after failover.
Auto Save on Crash or Rollover
Exception information for MASTER or standby units is stored in the flash:/TRACE_LOG_DIR directory. This directory contains
files that save trace information when there has been a task crash or timeout.
On a MASTER unit, you can reach the TRACE_LOG_DIR files by FTP or by using the show file command from the
flash://TRACE_LOG_DIR directory.
On a Standby unit, you can reach the TRACE_LOG_DIR files only by using the show file command from the flash://
TRACE_LOG_DIR directory.
NOTE: Non-management member units do not support this functionality.
S5000 Debugging and Diagnostics 1001