Administrator Guide

Table Of Contents
NOTE: The system reboots when the offline diagnostics completes. This is an automatic process in default mode. A
warning message appears when you implement the offline stack-unit command:
Warning - offline of stack unit will bring down all the protocols and the unit
will be operationally down, except for running Diagnostics. Proceed with Offline-
Diags [confirm yes/no]:y
2. Confirm offline status.
EXEC Privilege mode
show system brief
Results are captured in one file whether for one unit or multiple units.
3. Start diagnostics on the unit.
diag
When the tests are complete, the system displays the syslog Message 1 shown and automatically reboots the unit.
Dell#00:20:26 : Diagnostic test results are stored on file: flash:/TestReport-SU-0.txt
Dell#00:20:31: %Z9000:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 0
Diags completed... Rebooting the system now!!!
Diagnostic results are printed to a file in the flash using the filename format TestReport-SU-<stack-unit>.txt.
4. View the results of the diagnostic tests.
EXEC Privilege mode
show file flash://
5. View offline diagnostics.
show diag information or show diag stack-unit
The following example shows how to take a Z-Series stack unit offline.
Dell#offline stack-unit 0
Warning - offline of stack unit will bring down all the protocols and
the unit will be operationally down, except for running Diagnostics.
Please make sure that stacking/fanout not configured for Diagnostics execution.
Also reboot/online command is necessary for normal operation after the offline command
is issued.
Proceed with Offline [confirm yes/no]:yes
Dell#00:01:34: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 0 down - stack unit
offline
00:01:34: %STKUNIT0-M:CP %IFMGR-1-DEL_PORT: Removed port: Fo 0/
0,4,8,12,16,20,24,28,32,36,40,44,48,52,56,60,64,68,72,76,80,84,88,92,96,100,104,108,112,1
16,120,124,
The following example shows how to verify the offline/online status of a Z-Series stack unit.
Dell#show system brief | no-more
Stack MAC : 00:01:e8:a9:81:9e
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
--------------------------------------------------------
0 Management offline Z9000 Z9000 9-0-0-0 128
1 Member not present
2 Member not present
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present
-- Power Supplies --
Unit Bay Status Type Temperature(deg C) FanSpeed(rpm)
----------------------------------------------------
0 0 up AC 40 13888
0 1 up AC 42 14851
Z-Series Debugging and Diagnostics
781