Administrator Guide

Table Of Contents
You may specify both bytes of the 2-byte S-Tag TPID. The range is from 0 to
FFFF. The default is 9100.
Defaults 0x9100
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of
the 2-byte S-Tag TPID.
8.2.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the C-Series and S-Series.
E-Series original
Command
Usage
Information
For specific interoperability limitations regarding the S-Tag TPID, refer to the Dell Networking OS
Configuration Guide.
The four characters you enter in the CLI for number are interpreted, as shown in the following table.
Number Resulting TPID
1 0x0001
10 0x0010
81 0x0081
8100 0x8100
Related
Commands
portmode hybrid sets a port (physical ports only) to accept both tagged and untagged frames. A port
configured this way is identified as a hybrid port in report displays.
vlan-stack trunk specifies a Layer 2 port or port channel as a trunk port to the Stackable VLAN
network.
vlan-stack trunk
Specify a Layer 2 port or port channel as a trunk port to the Stackable VLAN network.
Syntax
vlan-stack trunk
To remove a trunk port designation from the selected interface, use the no vlan-stack trunk
command.
Defaults Not configured.
Command Modes INTERFACE
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
VLAN Stacking 1271