Administrator Guide

Table Of Contents
service timestamps
To debug and log messages, add time stamps. This command adds either the uptime or the current time and date.
Syntax
service timestamps [debug | log] [datetime [localtime] [msec] [show-
timezone] | uptime]
To disable timestamping, use the no service timestamps [debug | log] command.
Parameters
debug (OPTIONAL) Enter the keyword debug to add timestamps to debug messages.
log (OPTIONAL) Enter the keyword log to add timestamps to log messages with
severity from 0 to 6.
datetime (OPTIONAL) Enter the keyword datetime to have the current time and date
added to the message.
localtime (OPTIONAL) Enter the keyword localtime to include the localtime in the
timestamp.
msec (OPTIONAL) Enter the keyword msec to include milliseconds in the timestamp.
show-timezone (OPTIONAL) Enter the keyword show-timezone to include the time zone
information in the timestamp.
uptime (OPTIONAL) Enter the keyword uptime to have the timestamp based on time
elapsed since system reboot.
Defaults Not configured.
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
8.1.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series Original command.
Usage
Information
If you do not specify parameters and enter service timestamps, it appears as service timestamps debug
uptime in the running-configuration.
To view the current options set for the service timestamps command, use the show running-
config command.
show alarms
View alarms currently active in the system.
Syntax
show alarms [threshold]
Control and Monitoring 107