Release Notes

Upgrade the CPLD
The S3048-ON system with Dell EMC Networking OS Version 9.14(2.10) requires System CPLD revision 10 and Module CPLD
revision 9.
NOTE: If your CPLD revisions are higher than the ones shown here, DO NOT make any changes. If you have questions
regarding the CPLD revision, contact technical support..
Verify that a CPLD upgrade is required
Use the following command to identify the CPLD version:
DellEMC#show revision
-- Stack unit 1 --
S3048-ON SYSTEM CPLD : 10
S3048-ON MODULE CPLD : 9
DellEMC#
Use the following command to view CPLD version that is associated with the Dell EMC Networking OS image:
DellEMC#show os-version
RELEASE IMAGE INFORMATION :
--------------------------------------------------------------------
Platform Version Size ReleaseTime
S-Series:SG-ON 9.14(2.10) 65838348 May 18 2021 08:37:00
TARGET IMAGE INFORMATION :
--------------------------------------------------------------------
Type Version Target checksum
runtime 9.14(2.10) Control Processor passed
BOOT IMAGE INFORMATION :
--------------------------------------------------------------------
Type Version Target checksum
boot flash 3.24.2.9 Control Processor passed
BOOTSEL IMAGE INFORMATION :
--------------------------------------------------------------------
Type Version Target checksum
boot selector 3.24.0.0-11
Control Processor passed
FPGA IMAGE INFORMATION :
--------------------------------------------------------------------
Card FPGA Name Version
stack-unit 1 S3048-ON SYSTEM CPLD 10
stack-unit 1 S3048-ON MODULE CPLD 9
DellEMC#
Upgrading the CPLD Image
NOTE:
The upgrade fpga-image stack-unit 1 booted command is hidden when using the FPGA Upgrade feature in the CLI.
However, it is a supported command and will be accepted when entered as documented.
NOTE: Ensure that the BIOS version is 3.24.0.0-11. You can verify this version using show system stack-unit 1 command.
To upgrade the CPLD image on S3048-ON, follow these steps.
1. Upgrade the CPLD image.
EXEC Privilege
9