Install Guide

Table Of Contents
[May 17 15:53:53]: CMD-(CLI):[show command-history]by default from console
[May 17 15:54:54]: CMD-(CLI):[end]by default from console
[May 17 15:55:00]: CMD-(CLI):[show logging]by default from console
[May 17 15:55:12]: CMD-(CLI):[show clock]by default from console
[May 17 15:55:22]: CMD-(CLI):[show running-config]by default from console
[May 17 15:55:27]: CMD-(CLI):[show command-history]by default from console
Upgrading Dell EMC Networking OS
To upgrade Dell EMC Networking Operating System (OS), refer to the Release Notes for the version you want to load on the
system.
You can download the release notes of your platform at https://www.force10networks.com. Use your login ID to log in to the
website.
Using HTTP for File Transfers
Stating with Release 9.3(0.1), you can use HTTP to copy files or configuration details to a remote server. To transfer files to an
external server, use the copy source-file-url http://host[:port]/file-path command.
Enter the following source-file-url keywords and information:
To copy a file from the internal FLASH, enter flash:// followed by the filename.
To copy the running configuration, enter the keyword running-config.
To copy the startup configuration, enter the keyword startup-config.
To copy a file on the USB device, enter usbflash:// followed by the filename.
In the Dell EMC Networking OS release 9.8(0.0), HTTP services support the VRF-aware functionality. If you want the HTTP
server to use a VRF table that is attached to an interface, configure that HTTP server to use a specific routing table. You can
use the ip http vrf command to inform the HTTP server to use a specific routing table. After you configure this setting, the
VRF table is used to look up the destination address.
NOTE: To enable HTTP to be VRF-aware, as a prerequisite you must first define the VRF.
You can specify either the management VRF or a nondefault VRF to configure the VRF awareness setting.
When you specify the management VRF, the copy operation that is used to transfer files to and from an HTTP server utilizes
the VRF table corresponding to the Management VRF to look up the destination. When you specify a nondefault VRF, the VRF
table corresponding to that nondefault VRF is used to look up the HTTP server.
However, these changes are backward-compatible and do not affect existing behavior; meaning, you can still use the ip http
source- interface command to communicate with a particular interface even if no VRF is configured on that interface
NOTE: If the HTTP service is not VRF-aware, then it uses the global routing table to perform the look-up.
To enable an HTTP client to look up the VRF table corresponding to either management VRF or any nondefault VRF, use the ip
http vrf command in CONFIGURATION mode.
Configure an HTTP client with a VRF that is used to connect to the HTTP server.
CONFIGURATION MODE
DellEMC(conf)#ip http vrf {management | <vrf-name>}
Verify Software Images Before Installation
To validate the software image on the flash drive, you can use the MD5 message-digest algorithm or SHA256 Secure Hash
Algorithm, after the image is transferred to the system but before the image is installed. The validation calculates a hash value
of the downloaded image file on systems flash drive, and, optionally, compares it to a Dell EMC Networking published hash for
that file.
54